XMC0 系列专用接触器


XMC0 系列专用接触器资料下载
Description

Hongfa’s Definite Purpose Contactor XMC0 meets the rigorous demands of the HVAC, refrigeration, heating, data processing, welding, elevators, hoist & cranes, pool, commercial spa, and food service equipment industries. The contactor series meet and exceed the requirements for IEC 60947-4-1, GB 14048.4, UL 508, UL 60947-4-1, and UL 1995.

Features

1.    Tools-free accessories for quick & easy snap on assembly.

2.    Various terminal options for specific application.

3.    Universal mounting plate.

4.    Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

5.    Class F (155°C) Coil insulation systems with a broad range of 50/60Hz voltage offerings.

6.    Protective coil cover option available for the 1 & 2 pole contactors.

7.    UL(USR/CNR) and CCC approved, some models SEMKO, KETI or TÜV plus.

Environmental characteristics

Protective treatment

Total climate tropical use “TH”

Operating position

Vertical or Horizontal

(Metal/Plastic base mounting)

Ambient temperature

Operation

-40°C+70°C/-40°F+158°F

Storage

-40°C+70°C /-40°F+158°F

Relative humidity

90-95%RH at40°C

Pollution degree

3

 

Pole Characteristics

Full Load Amps(FLA)

Poles

Voltage

Locked Rotor Amps (LRA)

Resistive amps rating (RES)

Maximum Horsepower(HP)

Catalog Number

Voltage

Single

Phase

Three

Phase

25

1

240/277

480

600

150

-

-

35

240/277

2

-

XMC0-257*

XMC0-251*

32

1

240/277

480

600

180

150

120

40

240/277

2

-

XMC0-327*

XMC0-321*

40

1

240/277

480

600

240

-

-

50

240/277

3

-

XMC0-407*

XMC0-401

25

2

240/277

480

600

150

125

100

35

240/277

3

-

XMC0-252*

32

2

240/277

480

600

180

150

120

40

240/277

3

-

XMC0-322*

40

2

240/277

480

600

240

200

160

50

240/277

3

-

XMC0-402*

25

2

3

240/277

480

600

150

125

100

35

240/277

480

600

3

-

-

5

7.5

10

XMC0-253A*

XMC0-253*

32

2

3

240/277

480

600

180

150

120

40

240/277

480

600

3

-

-

7.5

10

15

XMC0-323A*

XMC0-323*

40

2

3

240/277

480

600

240

200

160

50

240/277

480

600

5

-

-

10

15

20

XMC0-403A*

XMC0-403*

50

2

3

240/277

480

600

300

250

200+

63

240/277

480

600

5

-

-

15

20

25

XMC0-503A*

XMC0-503*

63

2

3

240/277

480

600

360

300

240+

75

240/277

480

600

7.5

-

-

20

25

30

XMC0-633A*

XMC0-633*

50

2

3

240/277

480

600

300

250

200

63

240/277

480

600

5

-

-

15

20

25

XMC0-503A*Z

XMC0-503*Z

63

2

3

240/277

480

600

360

300

240

75

240/277

480

600

7.5

-

-

20

25

30

XMC0-633A*Z

XMC0-633*Z

75

2

3

240/277

480

600

450

375

300

94

240/277

480

600

15

-

-

25

40

40

XMC0-753A*

XMC0-753*

90

2

3

240/277

480

600

540

450

360

120

240/277

480

600

15

-

-

30

50

50

XMC0-903A*

XMC0-903*

    Notes:

1.     All the models also could be marked or used for the actual applications which have less contact ratings than the certificated ratings. The rating can be Voltage,FLA, LRA or RES.

2.     All the ratings have not “Break All Lines” restriction, except the rating “600VAC 50FLA/200LRA” for “XMC0-50 without Z” and “600VAC 63FLA/240LRA” for “XMC0-63 without Z”.

3.     Contact factory representative for Cd free option.

全球服务网点